From: Sympathetic-mediated blunting of forearm vasodilation is similar between young men and women
 | Effect of sex (p value) | Effect of SYMP (p value) | Interaction (p value) |
---|---|---|---|
Peak forearm VC change (%) | 0.97 | < 0.0001 | 0.42 |
Mean forearm VC change (%) | 0.84 | < 0.0001 | 0.94 |
Peak brachial artery BF change (%) | 0.95 | < 0.0001 | 0.25 |
Mean brachial artery BF change (%) | 0.73 | 0.03 | 0.54 |
Hand oxygenation after cuff inflation (%) | 0.70 | 0.16 | 0.54 |
Hand oxygenation after cuff release (%) | 0.004 | 0.009 | 0.80 |
Brachial artery FMD (%) | 0.03 | < 0.0001 | 0.03 |
FMD normalized to baseline diameter (% × cm) | 0.25 | < 0.0001 | 0.11 |
FMD normalized to cumulative shear stress (e−005%/s−1 × 60 s) | 0.08 | < 0.0001 | 0.34 |
TPR change (%) | 0.04 | 0.01 | 0.03 |
MAP change (%) | 0.41 | < 0.0001 | 0.43 |
Heart rate change (%) | 0.98 | < 0.0001 | 0.83 |
Cardiac output change (%) | 0.75 | 0.50 | 0.55 |
Cardiac stroke volume change (%) | 0.22 | 0.23 | 0.85 |